记得有次在在线课程的微信群讨论时,
有同学问我关于液相色谱柱的再生问题。
今天就来给大家讲讲如何进行色谱柱的再生。
通常情况下,
对于常用的反相色谱柱出现了严重的柱效降低需要考虑再生时,
建议大家用以下流程来进行冲洗:
· 【冲洗流程】 ·
•
···········♦ 1 ♦···········
20倍柱体积水:乙腈= 95%:5%
(用于移除系统中缓冲盐,可根据常用缓冲盐浓度调整比例)
···········♦ 2 ♦···········
20倍柱体积 乙腈
···········♦ 3 ♦···········
5倍柱体积 异丙醇
···········♦ 4 ♦···········
20倍柱体积 正己烷
···········♦ 5 ♦···········
20倍柱体积 乙腈
20倍柱体积 水:乙腈=95%:5% (可与步骤1保持相同的比例)
···········♦ 6 ♦···········
用所需的流动相比例重新平衡色谱柱
关于色谱柱的再生,我相信大家能看到很多相关文章,
建议大家可以根据实际需求来选择再生条件。
Elsa 老师今天要和大家讲的是关于上文给出的条件的柱体积的问题。
·············································································♣
实际上在色谱柱冲洗时,
很多实验室习惯用冲洗时间来评价是不是达到我们想要的效果。
例如某位师傅告诉你把这个柱子冲半个小时就可以了。
然而色谱柱的冲洗应该使用冲洗的溶剂体积来评价冲洗效果。
例如这次提到的20倍柱体积的乙腈冲洗色谱柱是指什么呢?
其实柱体积需要按照你使用的色谱柱的内径和柱长来计算。
· 【公式如下】 ·
•
通过公式就很容易算出柱体积了,
例如一根4.6mm内径,150 mm柱长的色谱柱柱体积为:
♣····················································································································································································
····················································································································································································♣
如果要用20倍柱体积的乙腈冲洗色谱柱就需要约34mL的乙腈,
假设你的柱流量是1mL/min,那就要用乙腈冲洗34分钟。
当柱流量是1.5 mL/min时就需要用乙腈冲洗约23分钟。
不知道这样的解释大家能理解么?
以后在色谱学堂微信群和大家讨论色谱柱冲洗时,
记得不要只和我说你曾经冲洗色谱柱用多少时间,
还要说流量哦!
最后提醒大家,
冲洗色谱柱时,色谱柱的尾端不要接检测器,
接一个可以收纳废液的容器就行了。